calibrating_with_dados-lamp [2025/07/23 09:36] – angelegt torsten.roehlcalibrating_with_dados-lamp [2025/07/25 07:56] (aktuell) – [DADOS piSpectro] torsten.roehl
Zeile 13: Zeile 13:
  
 ^ **<color #00a2e8>pi</color><color #22b14c>Scec</color><color #ffc90e>tros</color><color #ff7f27>co</color><color #ed1c24>pe</color>**  // Spectroscope and DADOS calibration lamp with holder //^ ^ **<color #00a2e8>pi</color><color #22b14c>Scec</color><color #ffc90e>tros</color><color #ff7f27>co</color><color #ed1c24>pe</color>**  // Spectroscope and DADOS calibration lamp with holder //^
-|{{ :pispectro-hardware.png?600 |}}|+|{{ :pispectro:dados-pi.png?600 |}}|
 |A 3D-printed holder securely and precisely holds the DADOS calibration lamp on the spectroscope – this helps ensure quick and reliable calibration.| |A 3D-printed holder securely and precisely holds the DADOS calibration lamp on the spectroscope – this helps ensure quick and reliable calibration.|
  
Zeile 22: Zeile 22:
 ==== DADOS Reference Spectrum ==== ==== DADOS Reference Spectrum ====
  
-Based on the published spectral lines from Baader Planetarium as well as precise neon spectral data from NIST**a compact reference database for the DADOS calibration lamp was created. This can be imported into your own spectra when needed to allow quick and reliable calibration.+Based on the published spectral lines from Baader Planetarium as well as precise neon spectral data from NIST**a compact reference database for the DADOS calibration lamp was created**. This can be imported into your own spectra when needed to allow quick and reliable calibration.
  
 The corresponding reference spectrum is shown in the image below. It serves as a visual guide and facilitates the identification of characteristic neon lines, which is especially helpful for the initial calibration. The corresponding reference spectrum is shown in the image below. It serves as a visual guide and facilitates the identification of characteristic neon lines, which is especially helpful for the initial calibration.
Zeile 31: Zeile 31:
  
 | piSpectro calibration with DADOS | | piSpectro calibration with DADOS |
-|{{ :pispectro:neon_1.png?700 |}}|+|{{ :pispectro:dados-cal-01.png?600 |}}| 
 +|{{ :pispectro:dados-cal-06.png?800 |}}|
 |Shown is the piSpectro calibration with the associated reference spectrum. For this, the DADOS reference spectrum was overlaid to facilitate the calibration. Then calibration was performed. A very good match between the theoretical line spectrum and the actually recorded spectrum can be seen.| |Shown is the piSpectro calibration with the associated reference spectrum. For this, the DADOS reference spectrum was overlaid to facilitate the calibration. Then calibration was performed. A very good match between the theoretical line spectrum and the actually recorded spectrum can be seen.|
  